LIVESTOCK LIGHTING SPECIFICATION GUIDE

How to Prepare an LED Lighting Specification for Livestock Facilities

Define the environment, animal-management requirements and supplier evidence before selecting a luminaire.

A Livestock Lighting Specification Starts Before Product Selection

Livestock luminaires can operate 12-18 hours a day in humid, dusty and ammonia-rich conditions. A useful specification therefore does more than name an IP rating or a wattage: it records where the light will be installed, how that zone is cleaned, what the animal-management programme requires and what evidence the supplier must provide.

This guide is designed for buyers preparing an RFQ, tender schedule or project brief across dairy, poultry and pig facilities. It complements—not replaces—the animal-specific guidance in ShineLong’s chicken-farm lighting guide.

STEP 01Map Each ZoneSeparate animal rooms, washdown areas, corridors and service spaces.
STEP 02Set Performance CriteriaDefine lux, light schedule, dimming, distribution and maintenance needs.
STEP 03Request EvidenceCompare data sheets, test reports, controls and warranty terms.
LED tubular lights installed in a dairy-cow housing environment
Farm zones and cleaning routines should be captured before fixture selection.

What Information Should a Livestock Lighting RFQ Include?

Ask the farm manager, installer and lighting supplier to work from the same project inputs. This prevents a single general-purpose fixture from being specified across areas with different animal, cleaning and maintenance requirements.

Building and Installation Inputs

  • Zone name, dimensions and mounting height
  • Mounting method and existing electrical arrangement
  • Dust, humidity, ammonia and impact exposure
  • Cleaning method, frequency, water temperature and pressure
  • Access requirements for inspection and replacement

Lighting and Management Inputs

  • Animal type, housing stage and daily management routine
  • Target lux at the animal level and uniformity requirement
  • Photoperiod, scheduled transitions and blackout requirements
  • Flicker performance, dimming protocol and control interface
  • Required documents, certifications, warranty and project approvals

How to Divide a Livestock Facility Into Lighting Specification Zones

ZoneSpecification FocusInformation to Confirm
Animal-Housing ZoneStable light level, distribution, flicker performance and controllable transitions.Target lux at animal level, photoperiod, mounting height, glare considerations and dimming method.
Wet or Washdown ZoneIngress protection, corrosion resistance, sealing and cleaning compatibility.Water pressure, temperature, detergent exposure, cable entry and required IP/IK evidence.
Feed, Service or Corridor ZoneSafe access, maintenance practicality and task-appropriate visibility.Operating hours, sensor or switching logic, maintenance access and emergency requirements.
Exterior or Transition ZoneWeather exposure, mounting security and control handover between areas.Outdoor exposure, temperature range, cable routing and fixture mounting detail.
Procurement rule: Specify the environment and use case first; only then compare fixture ratings, optics, driver options and price. A high protection rating alone does not confirm that a fixture is suitable for every farm zone.

How Should Dairy, Poultry and Pig Requirements Appear in the Specification?

The table below preserves the planning ranges in the source brief while turning them into procurement inputs. Final targets should be confirmed through the farm’s management programme, local requirements and a project lighting design.

LED lighting installed in a poultry farm
Poultry-house lighting needs stable distribution and schedule-compatible controls.
Livestock ApplicationSource-Brief Planning RangeSpecification QuestionProject Evidence to Request
Dairy CowsLong-day programmes may use 16-18 hours of light; 150-200 lux at cow eye level; warm white around 3000K or natural white.How will the layout achieve uniform light at cow level without creating difficult maintenance zones?Photometric layout, mounting drawing, selected CCT, control schedule and maintenance plan.
Poultry20 lux during brooding and 5-10 lux during growing in the source brief; dimming and red-white programming may be considered by stage.Which spectrum, lux range and transition programme match the farm’s production stage?Flicker specification, dimming curve, control compatibility and poultry-management approval.
Pigs50-100 lux with a clear day-to-night transition in the source brief; compatible 0-10V or DALI dimming where required.Can the proposed system make gradual, repeatable transitions across the required zones?Control diagram, dimming protocol, scene schedule and installed-lighting commissioning plan.

The ranges are planning inputs from the supplied source brief, not universal operating prescriptions. Verify final values for the animal type, production stage, jurisdiction and farm-management programme.

Rancher IP69K LED tubular tri-proof light
Request the exact product configuration and supporting documentation for each zone.

What Should Buyers Check in a Livestock Lighting Submittal?

A manufacturer’s product page is a starting point, not a complete submittal. For high-washdown or corrosive areas, compare the precise selected configuration with its project documents. ShineLong’s Rancher IP69K LED tri-proof light is one option to evaluate where its documented configuration matches the site requirements.

  • Protection and construction: IP and IK declarations, enclosure material, cable entry, mounting hardware and washdown compatibility.
  • Optical performance: System efficacy, light distribution, beam angle, selected CCT, CRI and project photometric results.
  • Driver and controls: Flicker information, dimming protocol, compatible control hardware and transition behaviour.
  • Reliability evidence: Product data sheet, relevant test reports, warranty terms and service contact.
  • Installation evidence: Dimensions, wiring, mounting instructions, accessories and commissioning responsibilities.
```

Frequently Asked Questions About Livestock Lighting Specifications

Define the installation zone and its operating conditions first. Record the animal area or service function, mounting height, humidity, dust, ammonia exposure, cleaning method and access requirements before choosing a fixture or rating.
State the target lux at the animal or working level, then ask the supplier for a lighting layout that shows how the target will be achieved. The required level should be confirmed with the farm-management programme, animal type and production stage.
IP69K can be relevant where the selected fixture must suit demanding high-pressure washdown conditions. The project specification should state the actual cleaning method, water temperature, pressure, detergent exposure and installation details, then verify the chosen configuration with its documentation.
Request the exact model data sheet, photometric information, protection and material declarations, control compatibility, relevant test reports, mounting instructions, warranty terms and a clear list of any project-specific options.

Specify the Farm Environment Before Selecting the LED Fixture

ShineLong believes a useful livestock lighting specification connects animal-management needs with the actual building, cleaning routine, controls and maintenance plan. When those inputs are documented first, buyers can assess technical evidence and select the right configuration for every zone with greater confidence.

Need Help Reviewing a Livestock Lighting Specification?

Send your zone layout, mounting heights, cleaning method, target lux and control requirements. ShineLong can help review a suitable LED lighting configuration and supporting technical documents.

Get a Customized Solution

Latest Articles

Loading latest articles...

Leave a Comment

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Scroll to Top

Request Technical Support

Get professional advice on product selection, installation, and lighting requirements from our technical team.

Your information is secure and will never be shared with third parties.

Request Technical Documents

Get datasheets, certifications, test reports, and technical files directly from ShineLong.

Your information is secure and will never be shared with third parties.

Start Your Inquiry

Tell us what you need, and our team will reply within 24 hours.

Download Resources

We will send the resources to your mailbox once you have finished the email form. No Spam.

Start Your Project Solutions

Tell us about your project requirements, and our lighting engineers will prepare a suitable lighting solution within 24 hours.

Your information is secure and will never be shared with third parties.

Request a Quote

Get competitive pricing and professional support for your LED lighting requirements.

Your information is secure and will never be shared with third parties.

Get Full Product Catalog

Please enter your professional business email address to instantly unlock the catalog file download. No Spam.